Alloy | Mechanical and Electrical Properties of Copper Beryllium Strip% | ||||||
---|---|---|---|---|---|---|---|
Cu | Be | Co | Si | Ai | Fe | Total impurities | |
C17410 | Allowance | 0.15~0.50 | ≥ 0.2 | ≤ 0.6 | ≤ 0.15 | ≤ 0.15 | ≤ 0.5 |
Alloy | Temper | Proposed Hardness (HV/DPH) | Yield Strength 0.2% Offset | N / mm²: Tensile Strength | Electrical Conductivity%IACS | Elongation% |
---|---|---|---|---|---|---|
C17410 | TH02 | 180~230 | 550~690 | 665~790 | ≥45 | 10~20 |
TH04 | 210~278 | 690~830 | 760~895 | ≥45 | 7~17 |
Thickness / mm | 0.05 - 0.08 | > 0.08 - 0.10 | > 0.10 - 0.15 | > 0.15 - 0.20 | > 0.20 - 0.30 | > 0.30 - 0.40 | > 0.40 - 0.55 | > 0.55 - 0.70 | > 0.70 - 0.90 | > 0.90 - 1.20 | > 1.20 - 1.50 |
Deviation / mm | ±0.003 | ±0.004 | ±0.005 | ±0.006 | ±0.007 | ±0.010 | ±0.012 | ±0.015 | ±0.018 | ±0.020 | ±0.025 |
Width / mm | Sheet thickness | Strip thickness | |||||
---|---|---|---|---|---|---|---|
> 1.5 ~ 3.0 | > 3.0 ~ 5.0 | > 5.0 ~ 6.0 | 0.05 ~ 0.55 | 0.55 ~ 1.5 | |||
Width deviation | |||||||
≤ 100 | ± 1.0 | ± 1.0 | ± 2.5 | ± 0.1 | ± 0.2 | ||
> 100 - 200 | ± 1.0 | ± 1.0 | ± 2.5 | ± 0.2 | ± 0.3 | ||
> 200 - 300 | ± 1.0 | ± 1.2 | ± 2.5 | ± 0.3 | ± 0.4 | ||
Note: 1. If the allowable deviation requirement is single positive or single negative, take 2 times of each value in the table as the standard. 2. When the customer has special requirements for the width and its allowable deviation, it shall be negotiated by the supplier and the buyer and indicated in the contract. |